WebMar 19, 2024 · A Construction Site Safety Technician is a safety professional who has passed the Construction Site Safety Technician (CSST) course. The CSST course covers all aspects of on-the-job safety for the construction industry, forming the basis for a well rounded understanding of safety as it applies to the construction industry. The course …
(310.3) Arc-Resistant CSST UpCodes
The 2024 International Fuel Gas Code (IFGC) and International Residential Code (IRC) have reaffirmed (without any modifications) the requirements for the electrical protection of corrugated stainless steel tubing (CSST). CSST may be protected either by installation of an extra bonding connection (IFGC Section … See more Arc-resistant (black) CSST is characterized by a thick black jacket or a multi-layer black jacket system. The single-layer black jacket is designed to absorb arcing energy caused by a lightning strike … See more The grounding electrode system includes all of the grounding electrodes available and the grounding electrode conductor(s). All electrodes used … See more Existing steel or copper piping systems must be retroactively bonded when modified by adding yellow (non-arc-resistant) CSST to the system regardless of the length of CSST added. A piping system assembled … See more WebYou'll need to use the right connector, but yes, you can do that. Bonding CSST to a grounding electrode conductor is fine as long as you don't cut said grounding electrode conductor. To that end, you can use a clamp-on (mechanical) T-tap connector such as an Ilsco GTT-2-2 to make the connection. From there, you can run 6AWG copper (as per … criminal background checks reviews
Bonding CSST to electrical ground system
WebThe WARDFlex® CSST system is required to be bonded to the electrical service grounding system. The use of an independent grounding electrode could cause a difference in potential between the gas piping system and other metallic systems in the structure that are tied to the electrical service grounding system. WebMar 10, 2024 · According to a home inspection site that I've found useful in the past, the answer is "no, you do not need a bonding clamp to ground on the CSST fitting" as long as the upstream metal pipe is properly grounded according to current code on the house side of the gas meter. The CSST manufacturer may have additional requirements. From the … WebNov 21, 2024 · 4. The pipe only needs to be bonded at 1 place, usually this is at the meter. If it is bonded there the entire system is attached to a grounding bond and would be legal. The gas pipe is bonded to prevent it from becoming electrified by a short. budget tax changes 2022